Horizontal Laminar Flow Hood Table Top (Clean Bench) | 4003 Series
Liberty Industries 4003 Series Horizontal Laminar Flow Table Top unit is efficient, an economical unit that is designed for table top use as a single unit or can be placed side-by-side. Manufactured in 3/4" novaply, white high-pressure plastic laminate on exposed surfaces sealed to prevent shedding of particulates and contamination adherence. Liberty offers the only unit in the industry with work zone definition. Available in stainless steel, quoted on request.
(16)
Horizontal Laminar Flow Hood Slimline Work Station (Clean Bench)
Liberty Industries 4003 Series Horizontal Laminar Flow Table Top unit is efficient, an economical unit that is designed for table top use as a single unit or can be placed side-by-side. Manufactured in 3/4" novaply, white high-pressure plastic laminate on exposed surfaces sealed to prevent shedding of particulates and contamination adherence. Liberty offers the only unit in the industry with work zone definition. Available in stainless steel, quoted on request.
(4)
Horizontal Laminar Flow Work Console (Clean Bench) | 4010 Series
Liberty Industries 4003 Series Horizontal Laminar Flow Table Top unit is efficient, an economical unit that is designed for table top use as a single unit or can be placed side-by-side. Manufactured in 3/4" novaply, white high-pressure plastic laminate on exposed surfaces sealed to prevent shedding of particulates and contamination adherence. Liberty offers the only unit in the industry with work zone definition. Available in stainless steel, quoted on request.
(12)
Peripheral Laminar Flow Cleanroom Hood (Clean Bench) | 4015 Series
Liberty Industries 4003 Series Horizontal Laminar Flow Table Top unit is efficient, an economical unit that is designed for table top use as a single unit or can be placed side-by-side. Manufactured in 3/4" novaply, white high-pressure plastic laminate on exposed surfaces sealed to prevent shedding of particulates and contamination adherence. Liberty offers the only unit in the industry with work zone definition. Available in stainless steel, quoted on request.
Laminar Flow Fume Hood Table Top (Clean Bench)
The Liberty 4003 Slimline Series Laminar Flow Work Station offers the economy and space saving for critical protection required in a bio-medical environment. Also available in stainless steel, quoted on request.
(5)
Polypropylene Laminar Flow Fume Hood (PolyPro)
The Liberty 4003 Slimline Series Laminar Flow Work Station offers the economy and space saving for critical protection required in a bio-medical environment. Also available in stainless steel, quoted on request.
(3)
Horizontal Laminar Flow Equipment
The Liberty 4003 Slimline Series Laminar Flow Work Station offers the economy and space saving for critical protection required in a bio-medical environment. Also available in stainless steel, quoted on request.
(5)
Vertical Laminar Flow Fume Hood (Clean Bench) | 4070 Series
The Liberty 4003 Slimline Series Laminar Flow Work Station offers the economy and space saving for critical protection required in a bio-medical environment. Also available in stainless steel, quoted on request.
(6)
Laminar Flow Station Table Top (Clean Bench)
Designed for assembly, production and laboratory applications requiring dust-free ambient conditions. It generates laminar air flow to reduce eddy currents set up by equipment or personnel, eliminates the need for special cleanroom garments, affords positive protection for the work surface against contamination from surrounding air. 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Also available in 16 ga, cold rolled steel, painted white, or stainless steel. Available work surfaces, include stainless steel, PVC, Polypro or other materials. Optional remote work surface on legs for minimum vibration and acrylic side panels. Prefilters consist of 1" thick, 30% NBS, Final filters are HEPA type 99.99% efficient for particles 0.3 micron and larger. Positive filter sealing to prevent filter bypass. Less than 100 particles per cubic foot 0.3 micron and larger, Class 100 (ISO 5) conditions per Federal Standard 209 and ISO 14644-1. Available in stainless steel, quoted on request.
Vertical Laminar Flow Hood (Clean Bench) | 5010T Series
Designed for assembly, production and laboratory applications requiring dust-free ambient conditions. It generates laminar air flow to reduce eddy currents set up by equipment or personnel, eliminates the need for special cleanroom garments, affords positive protection for the work surface against contamination from surrounding air. 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Also available in 16 ga, cold rolled steel, painted white, or stainless steel. Available work surfaces, include stainless steel, PVC, Polypro or other materials. Optional remote work surface on legs for minimum vibration and acrylic side panels. Prefilters consist of 1" thick, 30% NBS, Final filters are HEPA type 99.99% efficient for particles 0.3 micron and larger. Positive filter sealing to prevent filter bypass. Less than 100 particles per cubic foot 0.3 micron and larger, Class 100 (ISO 5) conditions per Federal Standard 209 and ISO 14644-1. Available in stainless steel, quoted on request. (6)
Vertical Laminar Flow Hood Console (Clean Bench) | 5010 Series
Designed for assembly, production and laboratory applications requiring dust-free ambient conditions. It generates laminar air flow to reduce eddy currents set up by equipment or personnel, eliminates the need for special cleanroom garments, affords positive protection for the work surface against contamination from surrounding air. 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Also available in 16 ga, cold rolled steel, painted white, or stainless steel. Available work surfaces, include stainless steel, PVC, Polypro or other materials. Optional remote work surface on legs for minimum vibration and acrylic side panels. Prefilters consist of 1" thick, 30% NBS, Final filters are HEPA type 99.99% efficient for particles 0.3 micron and larger. Positive filter sealing to prevent filter bypass. Less than 100 particles per cubic foot 0.3 micron and larger, Class 100 (ISO 5) conditions per Federal Standard 209 and ISO 14644-1. Available in stainless steel, quoted on request. (6)
Vertical Laminar Flow "Econobench" (Clean Bench)
Designed for assembly, production and laboratory applications requiring dust-free ambient conditions. It generates laminar air flow to reduce eddy currents set up by equipment or personnel, eliminates the need for special cleanroom garments, affords positive protection for the work surface against contamination from surrounding air. 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Also available in 16 ga, cold rolled steel, painted white, or stainless steel. Available work surfaces, include stainless steel, PVC, Polypro or other materials. Optional remote work surface on legs for minimum vibration and acrylic side panels. Prefilters consist of 1" thick, 30% NBS, Final filters are HEPA type 99.99% efficient for particles 0.3 micron and larger. Positive filter sealing to prevent filter bypass. Less than 100 particles per cubic foot 0.3 micron and larger, Class 100 (ISO 5) conditions per Federal Standard 209 and ISO 14644-1. Available in stainless steel, quoted on request. (2)
Laminar Flow Filter Module (Clean Booth) | FM 500 Series
The 4015 utilizes a supplemental air curtain around the complete work peripheral edge area so that eddying and back currents are eliminated. It provides the most effective contamination control available in the industry. This additional curtain of air assures a higher degree of protection from outside contamination. The unit provides horizontal air flow in conjunction with a supplemental air intake around the perimeter of the work area. The air intake draws air in around the perimeter and substantially reduces the introduction of non-HEPA filtered air caused by items being placed into the work space and normal worker movements. Constructed of 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Available in 16 ga. cold rolled steel, painted white, or stainless steel with 1/4-inch clear acrylic side panels, Liberty Dust Guard 1" prefilters, 30% efficient NBS. HEPA type final filter 99.99% efficient on particles 0.3 micron and larger. Less than 100 particles per cubic foot 0.3 micron and larger, Meets Federal Standard 209 and ISO 14644-1, Class 100 (ISO 5) conditions. High capacity forward curved blowers with direct drive blower(s) motor, statically and dynamically balanced to maintain constant air flow without speed control or belt adjustment to twice the clean filter resistance. 120V 1 phase 60 HZ standard. 90 FPM + 20%. Noise level conforms to OSHA noise standards, D.O.P. test port 1 /2" N.P.T. plug to facilitate sampling of upstream concentration (option). Fluorescent, 125 ft. candle, at work surface , based on color/material of work surface. Available in stainless steel, quoted on request. (8)
Laminar Air Flow Tunnel
The 4015 utilizes a supplemental air curtain around the complete work peripheral edge area so that eddying and back currents are eliminated. It provides the most effective contamination control available in the industry. This additional curtain of air assures a higher degree of protection from outside contamination. The unit provides horizontal air flow in conjunction with a supplemental air intake around the perimeter of the work area. The air intake draws air in around the perimeter and substantially reduces the introduction of non-HEPA filtered air caused by items being placed into the work space and normal worker movements. Constructed of 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Available in 16 ga. cold rolled steel, painted white, or stainless steel with 1/4-inch clear acrylic side panels, Liberty Dust Guard 1" prefilters, 30% efficient NBS. HEPA type final filter 99.99% efficient on particles 0.3 micron and larger. Less than 100 particles per cubic foot 0.3 micron and larger, Meets Federal Standard 209 and ISO 14644-1, Class 100 (ISO 5) conditions. High capacity forward curved blowers with direct drive blower(s) motor, statically and dynamically balanced to maintain constant air flow without speed control or belt adjustment to twice the clean filter resistance. 120V 1 phase 60 HZ standard. 90 FPM + 20%. Noise level conforms to OSHA noise standards, D.O.P. test port 1 /2" N.P.T. plug to facilitate sampling of upstream concentration (option). Fluorescent, 125 ft. candle, at work surface , based on color/material of work surface. Available in stainless steel, quoted on request. (4)
Adapt-A-Flow Laminar Flow Air Filter Unit
The 4015 utilizes a supplemental air curtain around the complete work peripheral edge area so that eddying and back currents are eliminated. It provides the most effective contamination control available in the industry. This additional curtain of air assures a higher degree of protection from outside contamination. The unit provides horizontal air flow in conjunction with a supplemental air intake around the perimeter of the work area. The air intake draws air in around the perimeter and substantially reduces the introduction of non-HEPA filtered air caused by items being placed into the work space and normal worker movements. Constructed of 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Available in 16 ga. cold rolled steel, painted white, or stainless steel with 1/4-inch clear acrylic side panels, Liberty Dust Guard 1" prefilters, 30% efficient NBS. HEPA type final filter 99.99% efficient on particles 0.3 micron and larger. Less than 100 particles per cubic foot 0.3 micron and larger, Meets Federal Standard 209 and ISO 14644-1, Class 100 (ISO 5) conditions. High capacity forward curved blowers with direct drive blower(s) motor, statically and dynamically balanced to maintain constant air flow without speed control or belt adjustment to twice the clean filter resistance. 120V 1 phase 60 HZ standard. 90 FPM + 20%. Noise level conforms to OSHA noise standards, D.O.P. test port 1 /2" N.P.T. plug to facilitate sampling of upstream concentration (option). Fluorescent, 125 ft. candle, at work surface , based on color/material of work surface. Available in stainless steel, quoted on request.
Pure Air System | HEPA Air Purifier
The 4015 utilizes a supplemental air curtain around the complete work peripheral edge area so that eddying and back currents are eliminated. It provides the most effective contamination control available in the industry. This additional curtain of air assures a higher degree of protection from outside contamination. The unit provides horizontal air flow in conjunction with a supplemental air intake around the perimeter of the work area. The air intake draws air in around the perimeter and substantially reduces the introduction of non-HEPA filtered air caused by items being placed into the work space and normal worker movements. Constructed of 3/4-inch novaply, white high-pressure plastic laminate on exposed surfaces. Interior surfaces sealed to prevent shedding of particulates. Available in 16 ga. cold rolled steel, painted white, or stainless steel with 1/4-inch clear acrylic side panels, Liberty Dust Guard 1" prefilters, 30% efficient NBS. HEPA type final filter 99.99% efficient on particles 0.3 micron and larger. Less than 100 particles per cubic foot 0.3 micron and larger, Meets Federal Standard 209 and ISO 14644-1, Class 100 (ISO 5) conditions. High capacity forward curved blowers with direct drive blower(s) motor, statically and dynamically balanced to maintain constant air flow without speed control or belt adjustment to twice the clean filter resistance. 120V 1 phase 60 HZ standard. 90 FPM + 20%. Noise level conforms to OSHA noise standards, D.O.P. test port 1 /2" N.P.T. plug to facilitate sampling of upstream concentration (option). Fluorescent, 125 ft. candle, at work surface , based on color/material of work surface. Available in stainless steel, quoted on request.